| Tests | Conditions | Unit | T00017 | T00028 | T00032 | T00011 | T00025 |
| Typical Application | / | / | Injection Moulding | Sheet Extrusion | Blow Moulding/ Blown Film |
||
| Specific Gravity | ASTM D792 | / | 1.48 | 1.29 | 1.39 | 1.59 | 1.27 |
| Melt-Flow-Index | 170-180℃/2.16 kg | g (10 min)-1 | 4.8 | 12.9 | 5.6 | 26.5 | 3.4 |
| Heat-Deflection-Temperature | ASTM D648 | ℃ | 80 | 54 | 82 | 54 | 86 |
| Strength at Yield | ASTM D638 | MN m-2 | 29.6 | 45.7 | 33.7 | 38.3 | 34.0 |
| Strength at Break | ASTM D638 | MN m-2 | 24.1 | 22.4 | 20.6 | 30.4 | 37.8 |
| Elongation at Yield | ASTM D638 | % | 9 | 7 | 13 | 4 | 41 |
| Elongation at Break | ASTM D638 | % | 30 | 48 | 30 | 8 | 509 |
| Flexural Strength | ASTM D790 | MN m-2 | 58.9 | 69.5 | 57.5 | 54.0 | 34.6 |
| Flexural Modulus | ASTM D790 | MN m-2 | 2220 | 2070 | 2170 | 2530 | 575 |
| Izod Impact Strength | ASTM D256 | J m-1 | 420.7 | 483 | 470.2 | 298.8 | 590 |
All information on this Test Report based on the present state of our knowledge and does not guarantee of any kind whatsoever, whether implied or expressed since conditions of use are outside our control. Each customer should establish his own rules and take proper steps appropriate to the circumstances within his control and must take responsibility for observing existing laws and regulations. This Test Report does not form part of the conditions of sale of our products and is of a general nature.

NTSQP Test Report